Cardiac output and its control
What sets cardiac output: heart rate and stroke volume, the three determinants of stroke volume, the Frank-Starling mechanism, how the venous return curve and the cardiac function curve meet, and how output is measured and manipulated at the bedside.
By the end of this page you should be able to
- Define cardiac output, cardiac index, stroke volume and ejection fraction, and give normal resting values.
- Explain preload, afterload and contractility, and how each changes stroke volume.
- Describe the Frank-Starling mechanism and its cellular basis.
- Explain how the cardiac function curve and the venous return curve together set the operating point.
- Describe the nervous, humoral and intrinsic control of heart rate and contractility.
- Outline how cardiac output is measured and what the Fick principle states.
Definitions and normal values
- Cardiac output = heart rate times stroke volume. At rest, roughly 70 beats per minute times about 70 mL, so about 5 L/min; it can rise four to six times in exercise, and more in athletes.
- Cardiac index is output divided by body surface area, about 2.5 to 4 L/min/m2, which lets you compare a small person with a large one.
- Stroke volume = end-diastolic volume minus end-systolic volume; ejection fraction is stroke volume divided by end-diastolic volume, normally about 0.6.
- The two ventricles must pump the same output over time, but they do so against very different afterloads: the right ventricle is a thin-walled volume pump, the left a thick-walled pressure pump.
- Output is distributed by regional resistance, so a normal total output tells you nothing about whether the gut or the kidney is being perfused.
The three determinants of stroke volume
Preload is the stretch of the myocyte at end-diastole. The true variable is sarcomere length, which cannot be measured, so clinicians use end-diastolic volume, and then its surrogates: central venous pressure, pulmonary artery occlusion pressure or an echocardiographic estimate. Every step away from sarcomere length adds error, and the biggest source is ventricular compliance: a stiff ventricle has a high pressure at a modest volume.
Afterload is the load the ventricle must overcome to eject, best thought of as wall stress during ejection. By the law of Laplace, wall stress is proportional to pressure times radius divided by twice the wall thickness, so afterload rises with aortic pressure and with a dilated ventricle, and falls as the wall thickens. Raising afterload lowers stroke volume for a given preload and contractility; a failing, dilated ventricle is especially afterload-sensitive, which is why vasodilatation can transform acute pulmonary oedema.
Contractility (inotropy) is the force the muscle generates at a given preload and afterload. It depends on the amount of calcium delivered to the myofilaments and their sensitivity to it. It rises with sympathetic stimulation, circulating catecholamines, digoxin and a faster heart rate, and falls with ischaemia, hypoxia, acidosis, sepsis, severe hypothermia, hypocalcaemia and negative inotropic drugs.
The Frank-Starling mechanism
Within physiological limits, the greater the end-diastolic volume, the greater the force of the next contraction. Two mechanisms explain it: stretch improves the overlap of actin and myosin towards the optimum, and, more importantly in cardiac muscle, stretch increases the sensitivity of troponin C to calcium, partly through changes in myofilament lattice spacing and titin-based strain.
The practical value of the mechanism is beat-to-beat matching. Any mismatch between the two ventricles or between venous return and output corrects itself: more blood arriving stretches the ventricle, which ejects more. It is also the basis of the cardiac function curve. Unlike skeletal muscle, healthy cardiac muscle does not have a clear descending limb; what looks like a falling limb in a failing heart usually reflects worsening mitral regurgitation, ischaemia and neurohumoral activation.
Two curves, one operating point
The heart cannot pump more than it receives. Draw flow against right atrial pressure and two relationships appear on the same axes.
The cardiac function curve rises and flattens: as filling pressure rises, the heart pumps more. Sympathetic stimulation lifts the whole curve; heart failure, tamponade and negative inotropes flatten it.
The venous return curve falls: as right atrial pressure rises, the pressure gradient driving blood back to the heart falls, and flow reaches zero when right atrial pressure equals the mean circulatory filling pressure (about 7 mmHg), the pressure in a stopped circulation. Giving fluid or constricting veins raises that pressure and shifts the curve to the right; haemorrhage or venodilatation shifts it left. The slope is set by venous resistance.
Where the curves cross is the operating point, which is why a fluid bolus alone, or an inotrope alone, usually produces a modest change in output, and why the patient who is both vasodilated and poorly contractile needs both addressed. It also explains why a spontaneously breathing patient has a slightly higher venous return during inspiration while positive pressure ventilation, which raises intrathoracic pressure, reduces it.
Control of heart rate and rhythm
- Vagal (parasympathetic) fibres reach the sinoatrial and atrioventricular nodes; acetylcholine acting on M2 receptors reduces the rate of phase 4 depolarisation and slows nodal conduction. Vagal tone dominates at rest; its withdrawal is the fastest way the body raises rate.
- Sympathetic fibres reach nodes and myocardium; noradrenaline acting on beta-1 receptors raises rate (chronotropy), conduction speed (dromotropy), force (inotropy) and the speed of relaxation (lusitropy) by raising cyclic AMP and phosphorylating calcium channels, phospholamban and troponin I.
- Reflexes: the arterial baroreflex corrects beat-to-beat changes in pressure; the Bainbridge reflex raises rate when the atria are stretched; the Bezold-Jarisch reflex can cause bradycardia and vasodilatation when the underfilled ventricle contracts hard, as in severe haemorrhage or spinal anaesthesia; raised intracranial pressure causes hypertension with bradycardia.
- Intrinsic effects: rate itself raises contractility (the Bowditch effect, through accumulated intracellular calcium), and a sudden rise in aortic pressure raises contractility over the next beats (the Anrep effect).
- At very high rates, diastolic filling time and coronary perfusion both shorten, so output eventually falls. A ventricle that depends on atrial filling, such as a hypertrophied or stenotic one, decompensates when atrial fibrillation removes the atrial contribution.
Measuring output
- Fick principle: the uptake of a substance by an organ equals blood flow times the arteriovenous concentration difference. Applied to oxygen across the lungs, output equals oxygen consumption divided by the arteriovenous oxygen content difference.
- Indicator dilution and thermodilution: inject a known amount of indicator or cold fluid and measure the area under the downstream concentration or temperature curve; flow is inversely proportional to that area.
- Echocardiography: stroke volume from the cross-sectional area of the outflow tract times the velocity-time integral.
- Pulse contour and bioreactance methods estimate output continuously from the arterial waveform or thoracic electrical signals, after calibration.
- Fluid responsiveness is better judged by dynamic signs (pulse pressure variation in a ventilated patient, response to a passive leg raise or a small bolus) than by any single static filling pressure.
Making the answer flow
- Define output, then break it into rate and stroke volume, then stroke volume into preload, afterload and contractility; answer in that order every time.
- Draw the two curves and show what shifts each. It is the clearest way to explain why a shocked patient needs volume, tone and inotropy considered separately.
- Use Laplace to explain afterload rather than calling it simply blood pressure.
- Say where each mechanism matters clinically: Starling for ventricular matching, the Bowditch effect for pacing, the baroreflex for the compensated bleeding patient.
Where marks are lost
- Equating preload with central venous pressure; compliance stands between them.
- Equating afterload with systemic vascular resistance and forgetting ventricular radius and wall thickness.
- Claiming a normal descending limb of the Starling curve in healthy cardiac muscle.
- Forgetting that cardiac output can be normal or high while tissue perfusion is poor, as in septic shock.
- Saying a faster rate always means a higher output.
Where this meets surgical practice
- In haemorrhage, tachycardia and vasoconstriction maintain blood pressure until a large volume is lost; a normal pressure can hide significant hypovolaemia.
- Raised intra-abdominal pressure from pneumoperitoneum or compartment syndrome reduces venous return and cardiac output.
Test yourself
Answer each one aloud or on paper before you open the model points; explaining the mechanism is what makes the MCQ options easy to judge.
- 1.
Define cardiac output and describe its determinants.
Show answer
- Volume ejected by one ventricle per minute; heart rate times stroke volume; about 5 L/min at rest, index 2.5 to 4 L/min/m2.
- Heart rate: autonomic balance, reflexes, drugs, temperature, rhythm.
- Stroke volume: preload, afterload, contractility.
- Note the rate and stroke volume interact: at very high rates filling time falls.
- 2.
What is preload, and how is it estimated clinically?
Show answer
- Myocyte stretch at end-diastole; strictly sarcomere length, practically end-diastolic volume.
- Surrogates: central venous pressure, pulmonary artery occlusion pressure, echocardiographic volumes, inferior vena cava measures.
- All are confounded by ventricular compliance, intrathoracic pressure and valve disease.
- Determinants of preload: venous return, so blood volume, venous tone, posture, intrathoracic pressure, atrial contraction and heart rate.
- 3.
Explain the Frank-Starling mechanism and its cellular basis.
Show answer
- Greater end-diastolic volume gives a greater force of contraction and stroke volume.
- Improved actin and myosin overlap, and increased calcium sensitivity of troponin C with stretch.
- Matches the two ventricles and matches output to venous return beat by beat.
- Curve is lifted by contractility and depressed in heart failure.
- 4.
Draw the cardiac function and venous return curves. What happens after a fluid bolus?
Show answer
- Flow against right atrial pressure; function curve rises and plateaus, venous return curve falls to zero at mean circulatory filling pressure about 7 mmHg.
- Intersection is the operating point.
- A bolus raises mean circulatory filling pressure and shifts the venous return curve right and parallel; output and right atrial pressure both rise.
- The size of the rise depends on the slope of the function curve, so it is small in heart failure.
- 5.
How does afterload affect stroke volume, and why does it matter in acute pulmonary oedema?
Show answer
- Afterload is ventricular wall stress during ejection; Laplace: pressure times radius over twice wall thickness.
- Raised afterload reduces stroke volume and raises myocardial oxygen demand.
- The failing dilated ventricle is afterload-sensitive, so reducing afterload raises stroke volume markedly.
- Nitrates and non-invasive ventilation reduce both preload and afterload, which is why symptoms improve quickly.
- 6.
What is contractility and how would you assess it?
Show answer
- Force at a given preload and afterload; dependent on calcium delivery and myofilament sensitivity.
- Load-independent index: slope of the end-systolic pressure-volume relation.
- Clinical surrogates: ejection fraction, fractional shortening, rate of pressure rise, all load-dependent.
- Raised by sympathetic drive and digoxin; depressed by ischaemia, hypoxia, acidosis, sepsis and negative inotropes.
- 7.
State the Fick principle and apply it to cardiac output.
Show answer
- Uptake of a substance by an organ equals flow times the arteriovenous concentration difference.
- Output equals oxygen consumption divided by the arteriovenous oxygen content difference.
- Needs oxygen consumption, arterial and mixed venous oxygen content; a pulmonary artery sample is required for the latter.
- Assumes a steady state and no shunt.
- 8.
How does positive pressure ventilation change cardiac output?
Show answer
- Raises intrathoracic and right atrial pressure, so reduces the gradient for venous return and shifts the venous return curve.
- Effect is greatest in the hypovolaemic or vasodilated patient, hence peri-intubation hypotension.
- High lung volumes raise pulmonary vascular resistance and right ventricular afterload.
- It can help the failing left ventricle by reducing left ventricular afterload and preload.
- 9.
Why can a patient with septic shock have a high cardiac output and still be inadequately perfused?
Show answer
- Low systemic vascular resistance, so output rises while pressure falls.
- Maldistribution of flow, microcirculatory shunting and capillary leak impair oxygen extraction.
- Mitochondrial dysfunction limits use of delivered oxygen; lactate rises despite a high output.
- Septic cardiomyopathy can coexist, so output may not be as high as the vasodilatation demands.
Practise this week
Week 6 in the other subjects
- Anatomy: Forearm and wrist
- Pathology: Shock
Not affiliated with the Royal Australasian College of Surgeons. Notes are a revision aid, not a substitute for the curriculum or for clinical guidelines.