Humidity, heat and temperature measurement
Heat, temperature and their units, specific heat and latent heat, the ways heat is lost from a patient, absolute and relative humidity and the dew point, how inspired gas is humidified naturally and by heat and moisture exchangers and heated humidifiers, how humidity is measured, and the methods and sites of temperature measurement.
By the end of this page you should be able to
- Distinguish heat from temperature and define specific heat capacity and latent heat.
- Describe the mechanisms of heat loss from an anaesthetised or critically ill patient and how they are reduced.
- Define absolute humidity, relative humidity and dew point, and explain why inspired gas must be humidified.
- Compare heat and moisture exchangers with heated humidifiers, and outline how humidity is measured.
- Describe the principles, advantages and errors of thermometers and temperature sensors, and the choice of measurement site.
Heat and temperature
Heat is a form of energy, measured in joules; temperature is a measure of the average kinetic energy of molecules and determines the direction in which heat flows, measured in kelvin (the SI unit, starting at absolute zero) or degrees Celsius (the same interval, offset by 273.15). The triple point of water (273.16 K) defines the kelvin.
Specific heat capacity is the heat needed to raise the temperature of 1 kg of a substance by 1 K: about 4.2 kJ/kg/K for water and about 3.5 kJ/kg/K for the body. This is why warming a cold patient takes a lot of energy, and why a litre of fluid at room temperature cools a patient measurably. Latent heat is the heat absorbed or released when a substance changes state without a change in temperature; the latent heat of vaporisation of water at body temperature is about 2.4 MJ/kg, which is why evaporation is so effective at cooling and why humidifying gas costs energy. Latent heat of vaporisation falls as temperature rises, reaching zero at the critical temperature.
Heat loss from the patient
- Radiation (about 40% in theatre): infrared emission from the skin to cooler surroundings, proportional to the fourth power of absolute temperature (Stefan-Boltzmann), independent of air temperature but dependent on the surroundings' temperature. Reduced by covering the patient and warming the room.
- Convection (about 30%): heat carried away by air moving over the skin, greater with laminar-flow ventilation. Reduced by covers and forced-air warming, which actively adds heat by convection.
- Evaporation (about 20 to 25%): from skin preparation, open body cavities, sweat and the respiratory tract. Reduced by limiting exposure and humidifying inspired gas.
- Conduction (small): to the table and through cold fluids. Warming mattresses and fluid warmers help.
- Under anaesthesia, temperature falls in three phases: a rapid fall of about 1 to 1.5 °C in the first hour from redistribution of heat from core to periphery as vasoconstriction is abolished; a slower linear fall as loss exceeds production; then a plateau when thermoregulatory vasoconstriction returns (or when active warming balances loss). Regional anaesthesia also abolishes vasoconstriction and shivering below the block. Prewarming reduces redistribution.
Humidity
Absolute humidity is the mass of water vapour in a given volume of gas (g/m³). Relative humidity is the actual amount of water vapour present as a percentage of the amount needed to saturate the gas at that temperature (or, equivalently, the ratio of actual to saturated vapour pressure). Because warm gas can hold much more water, the same absolute humidity gives a lower relative humidity at a higher temperature. The dew point is the temperature at which a gas becomes saturated as it cools and water condenses: the reason tubing collects water (rain-out) when warm humid gas cools.
At 37 °C, saturated gas holds about 44 g/m³ (a water vapour pressure of 47 mmHg). The nose and upper airway normally warm and humidify inspired air so that it is fully saturated at body temperature at the isothermic saturation boundary, about 5 cm below the carina. Medical gases from pipelines and cylinders are dry, and a tracheal tube bypasses the nose, so the lower airway must supply the water and heat. Breathing dry gas thickens secretions, impairs mucociliary clearance, damages epithelium, causes atelectasis and tube blockage, and loses heat and water (each litre of water evaporated takes about 2.4 MJ). Over-humidification or condensation risks water loading, infection and drowning the circuit.
Humidifying inspired gas
- Heat and moisture exchanger (HME): a passive device in the circuit. Exhaled warm, humid gas cools on a hygroscopic or hydrophobic element, condensing water and releasing latent heat; inspired gas then picks up that heat and water. Efficiency is about 60 to 80% (absolute humidity around 25 to 30 g/m³). Most include a filter (heat and moisture exchanging filter). Disadvantages: added dead space and resistance, which matter in small children and when tidal volume is low; blockage by secretions, blood or nebulised drugs; and reduced efficiency with large minute volumes or leaks.
- Heated water bath humidifier: gas passes over or through heated water and is then kept warm along a heated-wire circuit to stop rain-out, with a temperature probe near the patient. It can deliver gas fully saturated at body temperature and is used for long-term ventilation, high-flow nasal oxygen and in neonates. Hazards: overheating and airway burns, water overload, condensation, infection, electrical hazards and circuit disconnection.
- Nebulisers produce droplets rather than vapour (jet nebulisers use a Venturi; ultrasonic nebulisers use a vibrating piezoelectric crystal and can deliver very small droplets and a water load). They deliver drugs or water, not true humidity, and can over-hydrate.
Measuring humidity
- Hair hygrometer: a hair lengthens as humidity rises, moving a pointer; simple, works best at mid-range relative humidity.
- Wet and dry bulb hygrometer: evaporation from a wet bulb cools it below the dry bulb; the difference, read against tables, gives relative humidity.
- Regnault hygrometer: a silver tube containing ether is cooled by blowing air through it until dew forms; that temperature is the dew point, from which humidity is calculated.
- Electronic sensors: changes in electrical capacitance or resistance of a hygroscopic material, or mass spectrometry; fast enough for respiratory gases.
Measuring temperature
- Liquid expansion thermometers (mercury, alcohol) rely on thermal expansion; slow to respond, fragile and now largely replaced. A maximum thermometer has a constriction so the column stays at the highest reading.
- Thermistor: a semiconductor whose resistance falls (usually) as temperature rises, in a non-linear relationship that is linearised electronically; very small, fast and sensitive, used in probes and pulmonary artery catheters.
- Resistance thermometer: platinum wire whose resistance rises linearly with temperature, measured with a Wheatstone bridge; accurate and stable but larger.
- Thermocouple: two dissimilar metals (often copper and constantan) joined at two junctions; a temperature difference between the measuring and reference junctions generates a small voltage (the Seebeck effect). Small and fast; needs a reference junction at known temperature.
- Infrared thermometers: detect infrared radiation emitted from the tympanic membrane or skin; fast and convenient, but tympanic readings depend on the probe seeing the membrane and not the canal wall.
- Sites: core temperature is best measured in the pulmonary artery, distal oesophagus (lower third, behind the heart), nasopharynx or tympanic membrane, and bladder (lags with low urine flow); rectal temperature lags and is affected by faeces and cool blood returning from the legs; skin and axillary temperatures are peripheral and underestimate core temperature.
Pulling it together
- Separate heat (energy, joules) from temperature (kelvin) at the start, then use specific heat and latent heat to explain clinical cooling.
- Rank the mechanisms of heat loss and describe the three phases of hypothermia under anaesthesia.
- Define absolute and relative humidity and dew point before discussing devices.
- For each thermometer, name the physical principle, the relationship with temperature and one advantage and one disadvantage.
Common traps
- Using heat and temperature interchangeably.
- Saying the first hour's fall in temperature is mainly from heat loss to the room; it is redistribution.
- Saying relative humidity of saturated gas falls when it is cooled; it stays 100% and water condenses.
- Saying a thermistor's resistance always rises with temperature; most in clinical use fall.
- Calling a nebuliser a humidifier.
Where this meets anaesthesia
- Redistribution of heat from core to periphery causes most of the fall in core temperature in the first hour of anaesthesia.
- Measure core temperature in the distal oesophagus or nasopharynx during general anaesthesia.
Viva questions
Answer each one aloud, as you would to an examiner, before you open the model points.
- 1.
What is the difference between heat and temperature?
Show answer
- Heat is energy (joules); temperature reflects mean molecular kinetic energy and sets the direction of heat flow (kelvin).
- Specific heat capacity links them: energy to raise 1 kg by 1 K; body about 3.5 kJ/kg/K.
- Latent heat: energy for a change of state without temperature change.
- Clinical: warming a cold adult needs a large amount of energy; evaporation cools efficiently.
- 2.
How does an anaesthetised patient lose heat?
Show answer
- Radiation is largest, then convection, evaporation and conduction.
- Anaesthesia abolishes vasoconstriction and shivering and lowers thresholds.
- Three phases: redistribution in the first hour, linear loss, then plateau.
- Prevention: prewarming, forced air, fluid warmers, covering, warm room, humidification.
- 3.
Define relative humidity, absolute humidity and dew point.
Show answer
- Absolute: mass of water vapour per volume, g/m³.
- Relative: actual water vapour as a percentage of saturation at that temperature.
- Dew point: temperature at which gas becomes saturated on cooling and water condenses.
- Saturated gas at 37 °C holds about 44 g/m³, vapour pressure 47 mmHg.
- 4.
Why must inspired gas be humidified in an intubated patient?
Show answer
- Medical gases are dry and the tube bypasses the nose.
- Dry gas impairs cilia, thickens secretions, damages epithelium and causes tube blockage and atelectasis.
- Heat and water are lost from the airway; the isothermic saturation boundary moves distally.
- Short procedures tolerate HMEs; long-term ventilation needs active humidification.
- 5.
Compare a heat and moisture exchanger with a heated humidifier.
Show answer
- HME: passive, recycles exhaled heat and water, often filters; adds dead space and resistance, blocks with secretions, less efficient.
- Heated humidifier: active, can saturate at body temperature, heated circuit prevents rain-out.
- Heated humidifier hazards: burns, overhydration, condensation, infection, electrical risk.
- Choice depends on duration, tidal volume, secretions and patient size.
- 6.
How is humidity measured?
Show answer
- Hair hygrometer: hair length changes with humidity; best at middle range.
- Wet and dry bulb: evaporative cooling of the wet bulb, difference read from tables.
- Regnault: cool a silver tube with ether until dew forms; gives dew point.
- Electronic capacitance or resistance sensors; mass spectrometry.
- 7.
How does a thermistor work, and how does it compare with a thermocouple?
Show answer
- Thermistor: semiconductor whose resistance changes (usually falls) non-linearly with temperature; small, fast, sensitive; needs linearisation.
- Thermocouple: two dissimilar metal junctions produce a voltage proportional to the temperature difference (Seebeck effect).
- Thermocouple needs a reference junction; both are small and fast.
- Platinum resistance thermometer: linear and stable but larger.
- 8.
Where would you measure core temperature, and why?
Show answer
- Pulmonary artery is the reference; distal oesophagus, nasopharynx and tympanic membrane are close to core.
- Bladder is good if urine flow is adequate.
- Rectal lags and is affected by faeces and cool venous return from the legs.
- Axilla and skin are peripheral and underestimate core temperature.
- 9.
Why does a patient under regional anaesthesia become hypothermic?
Show answer
- Sympathetic block causes vasodilatation below the block, allowing redistribution of heat.
- Shivering is abolished in the blocked area, and central thresholds are altered.
- The patient may not feel cold, and temperature is often not measured.
- Monitoring and active warming are needed as for general anaesthesia.
Practise this week
- Primary MCQs: measurement and equipment