Ventilation, dead space and V/Q matching
Minute and alveolar ventilation, the kinds of dead space and how they are measured, the alveolar gas equation, the distribution of ventilation and perfusion in the upright lung, the V/Q spectrum from shunt to dead space, and how each mechanism of hypoxaemia behaves when oxygen is given.
By the end of this page you should be able to
- Define minute, alveolar and dead space ventilation and state the relationship between alveolar ventilation and arterial carbon dioxide.
- Distinguish anatomical, alveolar and physiological dead space and describe how each is measured.
- Use the alveolar gas equation and the alveolar-arterial oxygen difference.
- Describe the distribution of ventilation and perfusion in the upright lung and the resulting V/Q pattern.
- Explain shunt and dead space as the two ends of the V/Q spectrum and how they differ in response to oxygen.
- List the five mechanisms of hypoxaemia and distinguish them at the bedside.
Ventilation and dead space
Minute ventilation is tidal volume times respiratory rate, normally about 5 to 6 L/min at rest. Only part of it reaches perfused alveoli: alveolar ventilation is (tidal volume minus dead space) times rate.
This distinction has a direct clinical consequence. Because carbon dioxide excretion depends on alveolar ventilation, a patient who breathes rapidly and very shallowly can have a high minute ventilation and still be hypercapnic, since each small breath is mostly dead space. Arterial carbon dioxide is inversely proportional to alveolar ventilation (for a given production), so halving alveolar ventilation roughly doubles it: this is the single most useful relationship in respiratory physiology.
Anatomical dead space is the volume of the conducting airways, about 2 mL/kg or 150 mL in an adult. It is increased by a large tidal volume (airway distension), by neck extension and by added apparatus, and reduced by a tracheostomy, which bypasses the upper airway. It is measured by Fowler method, using the nitrogen washout profile of a single breath.
Alveolar dead space is alveoli that are ventilated but not perfused, which is negligible in health but important in pulmonary embolism, in low cardiac output and at the apex of an upright lung under positive pressure.
Physiological dead space is the sum of the two, measured by the Bohr equation, which compares the carbon dioxide in expired gas with that in arterial blood: the greater the dilution of expired carbon dioxide by gas from unperfused units, the greater the dead space fraction. Normally about a third of the tidal volume, it rises with age, in the upright position, with positive pressure ventilation and in any disease that destroys or occludes capillaries. The gap between end-tidal and arterial carbon dioxide is the bedside expression of alveolar dead space, which is why end-tidal values underestimate arterial in shock and in pulmonary embolism.
Alveolar gas
- Inspired gas is humidified at body temperature, so the saturated vapour pressure of water (47 mmHg at 37 degrees) must be subtracted from the total pressure before calculating the partial pressure of oxygen.
- The alveolar gas equation gives alveolar oxygen tension as the inspired tension minus arterial carbon dioxide divided by the respiratory quotient (about 0.8). Its practical consequences: hypercapnia necessarily lowers alveolar oxygen when breathing air, and supplementary oxygen easily compensates for pure hypoventilation.
- The alveolar-arterial oxygen difference is normally small (a few mmHg in the young, rising with age), and it separates causes of hypoxaemia: it is normal in hypoventilation and at altitude, and raised in shunt, V/Q mismatch and diffusion limitation.
- Oxygen cascade: the stepwise fall in oxygen tension from the atmosphere (about 160 mmHg) through humidified inspired gas and the alveolus (about 100) to arterial blood (slightly less, because of normal shunt and mismatch) and then to the mitochondrion (a few mmHg).
- The respiratory exchange ratio links carbon dioxide output to oxygen uptake and shifts with substrate: around 0.7 on fat, 1.0 on carbohydrate.
Distribution in the upright lung
- Ventilation is greater at the base. The weight of the lung makes intrapleural pressure less negative at the base, so basal alveoli start smaller, sit on the steeper part of the compliance curve and therefore expand more per unit pressure. Apical alveoli are already more expanded and change less.
- Perfusion is also greater at the base, and increases more steeply than ventilation because of the hydrostatic pressure gradient in the pulmonary circulation.
- Consequently the V/Q ratio is high at the apex (relative dead space, about 3) and low at the base (relative shunt, about 0.6), with an overall average near 0.8 to 1.0. The apex has higher oxygen and lower carbon dioxide tensions; the base the reverse.
- West zones describe the relationship between alveolar, arterial and venous pressure: in zone 1 alveolar pressure exceeds arterial, so no flow occurs (not present in health, but created by hypovolaemia or high airway pressure); in zone 2 flow depends on the difference between arterial and alveolar pressure; in zone 3 flow depends on the arteriovenous difference as in the rest of the body.
- Posture and ventilation change this. Lying supine evens out the vertical gradient but reduces functional residual capacity; in positive pressure ventilation the dependent lung receives relatively less ventilation and more perfusion, which worsens matching, and in the anaesthetised patient dependent atelectasis adds shunt.
- Hypoxic pulmonary vasoconstriction is the active mechanism that limits mismatch, diverting flow from poorly ventilated regions. It is blunted by vasodilators and by some anaesthetic agents, and it becomes harmful when hypoxia is global, because it then raises pulmonary vascular resistance and right ventricular afterload.
The V/Q spectrum
Every lung unit sits somewhere on a continuum. At one end is shunt (V/Q of zero): perfused but not ventilated, as in collapse, consolidation, pulmonary oedema, a plugged bronchus, or an intracardiac right to left shunt. At the other end is dead space (V/Q infinite): ventilated but not perfused, as in pulmonary embolism or very low cardiac output.
The two behave quite differently, and this is the practical core of the topic.
Shunt causes hypoxaemia that responds poorly to supplementary oxygen. Blood bypassing ventilated alveoli leaves with mixed venous tensions and mixes with capillary blood that is already nearly fully saturated, so raising the inspired oxygen can add very little content to the normal units. The flat upper part of the oxygen dissociation curve is the reason. Carbon dioxide, by contrast, is usually normal or low, because its dissociation curve is nearly linear and because the extra drive increases ventilation to the normal units enough to compensate. The treatment is recruitment: positive end-expiratory pressure, clearing the airway, draining the effusion, treating the oedema.
Dead space wastes ventilation. Gas leaving unperfused units is like inspired air and dilutes the expired carbon dioxide, so the patient must increase minute ventilation to keep arterial carbon dioxide normal. A patient who can increase ventilation stays normocapnic; one who cannot, because of fatigue, weakness, obstruction or sedation, becomes hypercapnic. Hypoxaemia from alveolar dead space alone is modest and responds to oxygen.
V/Q mismatch in between is the commonest cause of hypoxaemia in practice (asthma, chronic airflow limitation, pneumonia, atelectasis) and gives a hypoxaemia that improves with oxygen but with a widened alveolar-arterial difference.
The five mechanisms of hypoxaemia
- Hypoventilation: raised carbon dioxide, normal alveolar-arterial difference, corrects readily with oxygen (although the carbon dioxide remains). Causes: central depression, neuromuscular disease, chest wall problems, severe obstruction and fatigue.
- V/Q mismatch: raised alveolar-arterial difference, responds to oxygen. The commonest mechanism.
- Shunt: raised alveolar-arterial difference, responds poorly to oxygen, and a shunt fraction can be estimated by measuring the response to a high inspired oxygen.
- Diffusion limitation: raised alveolar-arterial difference, responds to oxygen, and matters mainly on exertion, at altitude and in interstitial disease.
- Reduced inspired oxygen tension: normal alveolar-arterial difference; altitude, enclosed space or an incorrect gas supply.
- Two extra situations are worth naming because the measurement misleads rather than the lung failing: a low mixed venous oxygen (shock, anaemia, high extraction) exaggerates the effect of any shunt, and carbon monoxide poisoning or methaemoglobinaemia impairs oxygen carriage and delivery while the arterial oxygen tension and the pulse oximeter may read normal.
Making the answer flow
- Say early that carbon dioxide is governed by alveolar, not minute, ventilation, and give the inverse relationship.
- Define the three dead spaces and name the measurement method for each.
- Explain the base and apex differences from first principles (pleural pressure gradient, compliance curve, hydrostatic pressure) rather than quoting the ratios.
- Use the response to oxygen to separate shunt from the other mechanisms, and explain it with the shape of the dissociation curve.
Where marks are lost
- Saying ventilation is greatest at the apex of an upright lung.
- Forgetting to subtract water vapour pressure when working through the alveolar gas equation.
- Claiming shunt hypoxaemia corrects with high flow oxygen.
- Treating end-tidal carbon dioxide as equal to arterial in shock or pulmonary embolism.
- Assuming a normal oxygen saturation means normal oxygen delivery in carbon monoxide poisoning or severe anaemia.
Where this meets anaesthesia
- One-lung ventilation creates a large shunt through the non-ventilated lung; hypoxic pulmonary vasoconstriction reduces it, and high concentrations of volatile agent blunt that response.
- Apparatus dead space from a heat and moisture exchanger, elbow and capnography adaptor is a large fraction of tidal volume in a small child.
Viva questions
Answer each one aloud, as you would to an examiner, before you open the model points.
- 1.
Define minute and alveolar ventilation and explain why the difference matters.
Show answer
- Minute ventilation is tidal volume times rate, about 5 to 6 L/min.
- Alveolar ventilation is (tidal volume minus dead space) times rate.
- Carbon dioxide excretion depends on alveolar ventilation, so rapid shallow breathing can be hypercapnic despite a high minute volume.
- Arterial carbon dioxide is inversely proportional to alveolar ventilation for a given production.
- 2.
Describe the types of dead space and how they are measured.
Show answer
- Anatomical: conducting airways, about 2 mL/kg, measured by the Fowler nitrogen washout method.
- Alveolar: ventilated but unperfused alveoli, negligible in health.
- Physiological: the sum, measured by the Bohr equation using expired and arterial carbon dioxide; normally about a third of tidal volume.
- Increased by age, upright posture, positive pressure ventilation, pulmonary embolism, low cardiac output and apparatus.
- 3.
Write and explain the alveolar gas equation.
Show answer
- Alveolar oxygen equals inspired oxygen tension minus arterial carbon dioxide divided by the respiratory quotient.
- Inspired tension uses dry barometric pressure, so water vapour pressure of 47 mmHg is subtracted first.
- Explains why hypercapnia lowers alveolar oxygen on air, and why supplemental oxygen corrects hypoventilation hypoxaemia.
- Used with the arterial value to derive the alveolar-arterial difference.
- 4.
Why does ventilation and perfusion vary down the upright lung?
Show answer
- Lung weight makes intrapleural pressure less negative at the base, so basal alveoli are smaller and more compliant and ventilate better.
- Hydrostatic pressure makes perfusion greater at the base, and it increases more steeply than ventilation.
- Therefore V/Q is high at the apex, about 3, and low at the base, about 0.6, averaging near 0.8 to 1.
- West zones describe the interplay of alveolar, arterial and venous pressures.
- 5.
Why does shunt hypoxaemia respond poorly to oxygen?
Show answer
- Shunted blood never meets alveolar gas, so it retains mixed venous tensions.
- Blood from ventilated units is already nearly fully saturated, so extra inspired oxygen adds little content because of the flat upper dissociation curve.
- Carbon dioxide is usually normal or low because its curve is nearly linear and ventilation to normal units increases.
- Treatment is recruitment and treating the cause, not more oxygen alone.
- 6.
What happens to gas exchange in pulmonary embolism?
Show answer
- Occluded vessels create alveolar dead space, so ventilation is wasted and the end-tidal to arterial carbon dioxide gap widens.
- Hyperventilation usually keeps arterial carbon dioxide low; a rising carbon dioxide suggests massive embolism or exhaustion.
- Hypoxaemia from redistribution of flow, atelectasis from surfactant loss, and in large emboli a low mixed venous oxygen from reduced output.
- Right ventricular afterload rises, and in severe cases output falls.
- 7.
List the mechanisms of hypoxaemia and how you would distinguish them.
Show answer
- Hypoventilation: raised carbon dioxide, normal alveolar-arterial difference.
- V/Q mismatch: widened difference, responds to oxygen; the commonest.
- Shunt: widened difference, poor response to oxygen.
- Diffusion limitation: widened difference, worse on exertion.
- Low inspired oxygen: normal difference; altitude or gas supply problem.
- 8.
What is hypoxic pulmonary vasoconstriction and when does it become harmful?
Show answer
- Constriction of pulmonary arterioles in response to alveolar hypoxia, diverting flow to better ventilated regions and limiting shunt.
- Mediated by inhibition of smooth muscle potassium channels with calcium entry.
- Harmful when hypoxia is global: raised pulmonary vascular resistance, right ventricular strain, pulmonary hypertension at altitude and in chronic lung disease.
- Blunted by vasodilators and some anaesthetic agents, which worsens shunt.
Practise this week
- Ventilator Waveform Reader
- Physiology Bench: move the graphs yourself
- Primary MCQs: physiology
- Primary SAQs, marked part by part
- Primary vivas
- Viva Examiner: practise answering aloud
Week 5 in the other subjects
- Pharmacology: Induction agents, sedatives and benzodiazepines
- Measurement and equipment: Medical gases, the anaesthetic machine and vaporisers