RANZCR Clinical Radiology Phase 1 Written (Anatomy and Applied Imaging Technology) 2023 Sitting 2: what the examiners said
Report released February 2024 · Summary checked
The headline
Definitions were the weak point: candidates confused dose thresholds with dose limits and gave partial definitions of effective dose and DRLs.
An independent plain-English summary. Fellowship Ready is not affiliated with or endorsed by the RANZCR. Read the original report on the RANZCR website. Read the full report.
Format: AIT: 60 MCQs and 9 constructed-response questions. Anatomy: labelling, MCQs, very short answers and short answers across six regions. Both 3 hours on Practique with online proctoring.
What candidates did well
Theoretical principles was the strongest AIT topic, including spatial and contrast resolution and AEC.
Most could describe the DRL dose-audit process and its time frame.
Fluoroscopy dose reduction and time, distance and shielding were well handled.
Head and neck was the strongest anatomy region, and short answers scored best.
Where marks were lost, and how to fix it
Definitions of dose quantities
What went wrong: Effective dose was defined incompletely, leaving out absorbed dose and the weighting factors.
How to fix it: Learn the full chain from absorbed dose to equivalent dose to effective dose, with each weighting factor.
Thresholds versus limits
What went wrong: Dose thresholds for tissue effects were confused with regulatory dose limits, and the lens limit was quoted without its 5-year averaging.
How to fix it: Keep two lists: biological thresholds (deterministic effects) and regulatory limits (with periods).
DRL purpose and response
What went wrong: Many believed a scanner must stop if a national DRL is exceeded, and some focused on a single patient instead of a sample.
How to fix it: Learn that exceeding a DRL triggers protocol review based on a patient sample, not withdrawal of equipment.
Protection at high photon energies
What went wrong: The effect of photon energy in PET on lead aprons was poorly understood, and thyroid collars in mammography were mishandled.
How to fix it: Relate shielding to photon energy and to where the primary beam actually falls.
Compton scatter and scatter reduction
What went wrong: Compton answers missed energy loss, momentum conservation and energy sharing; lowering kV was offered as scatter reduction without explaining how.
How to fix it: Write a full point-by-point account of Compton scatter, and explain the mechanism of each scatter-reduction technique.
Brain anatomy, levels and variants
What went wrong: Brain was the weakest anatomy region, and surface markings, vertebral levels and variants were poorly known.
How to fix it: Revise brain sectional anatomy and learn key vertebral-level landmarks.
Advice for the next sitting
Write complete definitions that include every component.
Know each regulatory limit in full, including its quantity and period.
State how each protective technique works, not just its name.
Original questions written to train the themes above (not questions from the exam). Answer each to see the explanation and why the other options are wrong.
Question 1 of 5Definitions of dose quantities
Which sequence correctly describes how effective dose is derived?
Pick an answer to see the explanation.
Fix what the examiners said
The same habits cost marks sitting after sitting. Each one has a short drill of questions from the Radiology bank that test exactly that habit.