RANZCR Clinical Radiology Phase 1 Written (Anatomy and Applied Imaging Technology) 2026 Sitting 1: what the examiners said
Report released May 2026 · Summary checked
The headline
Most marks were lost to imprecision, such as naming a unit when a quantity was asked or labelling the wrong side, rather than to missing knowledge.
An independent plain-English summary. Fellowship Ready is not affiliated with or endorsed by the RANZCR. Read the original report on the RANZCR website. Read the full report.
Format: Both papers were sat remotely on risr/Assess with online proctoring. AIT combines MCQs with constructed-response questions; Anatomy combines labelling, MCQs, very short answers and short answers, with a minimum standard in each body region.
What candidates did well
Dose communication, justification and dose quantities in a clinical context were generally handled well.
Characteristic X-ray production, the benefits of breast compression and cone beam CT geometry were strong AIT areas.
Gadolinium's T1-shortening effect and the location of MRI Zone IV were widely known.
In Anatomy, head and neck and cardiac anatomy were answered well, as were common CT, MRI and plain film images.
Where marks were lost, and how to fix it
Dose quantities versus units
What went wrong: Candidates named a unit when a dose quantity was asked, and converted to effective dose when tissue reactions depend on absorbed or equivalent dose.
How to fix it: Make a table of each quantity, its unit and what it predicts (tissue reaction or stochastic risk), and practise picking the right one for a clinical question.
Mammography dose concepts and AEC
What went wrong: Some believed individual mammograms have dose limits, linked mean glandular dose only to phantom testing, and placed AEC behind the detector.
How to fix it: Separate quality-control phantom limits from patient exposures, and learn how AEC works within modern digital mammography detectors.
Digital imaging and MTF
What went wrong: MTF curves, cycles per mm and the Nyquist limit were poorly interpreted, and pixel pitch was confused with detector element size.
How to fix it: Practise reading MTF curves and calculating the Nyquist frequency from pixel pitch until it is automatic.
Radiobiology beyond DNA
What went wrong: Answers stopped at DNA damage or at photon interactions without linking them to cell death, and water radiolysis products were muddled.
How to fix it: Learn the chain from interaction to free radicals to cellular outcome, naming each radiolysis product correctly.
Doppler and acoustic fundamentals
What went wrong: Candidates thought density or sound speed alone set echo amplitude and held several misconceptions about continuous-wave and pulsed-wave Doppler.
How to fix it: Anchor echo strength to acoustic impedance mismatch, and compare CW and PW Doppler side by side on sampling, aliasing and display.
Laterality and answer count in labelling
What went wrong: Many labels gave the wrong side of the patient or more answers than asked, and abbreviations such as ECA versus ICA changed the structure.
How to fix it: Check the image orientation marker before every paired label, give exactly the number asked, and write names in full when an abbreviation is ambiguous.
Original questions written to train the themes above (not questions from the exam). Answer each to see the explanation and why the other options are wrong.
Question 1 of 5Dose quantities versus units
After a long embolisation procedure, the team wants to estimate whether the patient's eye lenses are at risk of a radiation-induced opacity. Which quantity is most appropriate for this estimate?
Pick an answer to see the explanation.
Fix what the examiners said
The same habits cost marks sitting after sitting. Each one has a short drill of questions from the Radiology bank that test exactly that habit.