RANZCR Clinical Radiology Phase 1 Written (Anatomy and Applied Imaging Technology) 2024 Sitting 1: what the examiners said
Report released May 2024 · Summary checked
The headline
Imaging technology and spine anatomy were the weakest areas, and five candidates failed anatomy by falling below the minimum in a single region.
An independent plain-English summary. Fellowship Ready is not affiliated with or endorsed by the RANZCR. Read the original report on the RANZCR website. Read the full report.
Format: AIT: 60 MCQs and 9 constructed-response questions over 3 hours. Anatomy: labelling, MCQs, very short answers and short answers across six regions over 3 hours. Both online with proctoring on risr/Assess.
What candidates did well
Theoretical principles was the strongest AIT topic, including CT partial volume, fetal dose estimation and MR relaxation.
Mammography target and filter combinations and ultrasound contrast agents were well answered.
Brain was the strongest anatomy region, with CT coronary angiography and CT IVP labelling very well done.
Where marks were lost, and how to fix it
Interventional dose metrics
What went wrong: Candidates were unsure how cumulative air kerma is measured and how it relates to peak skin dose, and stated that tissue effects will occur rather than may occur.
How to fix it: Learn where the interventional reference point is and why CAK only approximates skin dose.
Dose limits and DRL statistics
What went wrong: Effective dose and time frames were omitted when quoting limits, and the median and 75th percentile were confused in the DRL process.
How to fix it: Quote each limit with its quantity and period, and know which statistic belongs to the facility and which to the national DRL.
Grids and noise
What went wrong: Grid construction was poorly understood, grids were confused with gamma camera collimators, and noise types other than quantum mottle were unknown.
How to fix it: Compare radiographic grids and nuclear medicine collimators side by side and learn the main sources of image noise.
CT dose and reconstruction
What went wrong: Few could link iterative reconstruction, noise, photon number and dose, or explain how DLP converts to effective dose.
How to fix it: Practise DLP-to-effective-dose conversions with region-specific coefficients.
Ultrasound and MR safety
What went wrong: Ultrasound image formation, range ambiguity and MR implant safety were weak.
How to fix it: Learn the timing basis of ultrasound image formation and the screening steps for implants before MRI.
Spine, limbs and arterial branches
What went wrong: Spine and limbs scored lowest; DSA branches, the lateral wrist and axial hip MRI were poorly labelled, and VSAQ branch names were often wrong.
How to fix it: Spend extra time on spine and limb imaging and learn visceral arterial branches from angiograms.
Advice for the next sitting
Read the whole question before answering.
Answer only what is asked, within the number of points requested.
Use precise dose terminology with time frames.
Describe tissue effects as possible outcomes above a threshold, not certainties.
Prepare every anatomy region, since each has a minimum standard.
Original questions written to train the themes above (not questions from the exam). Answer each to see the explanation and why the other options are wrong.
Question 1 of 5Interventional dose metrics
Which statement about the cumulative air kerma (CAK) displayed on an interventional fluoroscopy unit is correct?
Pick an answer to see the explanation.
Fix what the examiners said
The same habits cost marks sitting after sitting. Each one has a short drill of questions from the Radiology bank that test exactly that habit.